Thies Wind Systems
€5,875.00
Thies anemometer wind systems as a complete set
The models "Classic" or "Ultrasonic 2D compact" consisting of
- Measuring unit
- 20m connection cable
- LED display unit
The Ultrasonic Anemometer compact serves for the 2-dimensional acquisition of
the horizontal components of the wind velocity, the wind direction and the acoustic-virtual temperature.
Heated components:
• base plate
• cover plate
• sensor receiving sockets
• ultrasonic transducers
The following measurement
data are available:
• Orthogonal wind velocity vectors (X- and Y-distance)
• Scalar / vectorial wind velocity wind direction
• Acoustic-virtual temperature
The instrument is especially suitable for the use in the fields
of:
• Regenerative power generation, wind power plants
• Industry automation
• Wind warning devices, building construction and building security
• Traffic engineering, aviation and navigation
• Meteorology
• Climatology
The measurement principle allows, compared to the classic anemometers, an inertia-free measurement of running variable dimensions with highest precision and accuracy.
The data can be served
• analogically*, as standard signal or / and digitally in
• ASCII THIES- Format or
• binary as MODBUS RTU protocol
If necessary, the instrument is automatically heated at critical ambient temperatures. Thus,
the risk of malfunction caused by icing is minimized.
The model no. 4 3875 2x xxx is equipped with an additional baro transmitter.
* only in HD (half duplex) operation
no output of virtual temperature
|
Wind speed
|
|
|
Measuring range
|
0 ... 75 m/s
|
|
Resolution
|
0.1 m/s (standard)
0.01 m/s (special telegrams) |
|
Accuracy
|
±0.2 m/s rms ( < 5 m/s )
±2 % rms ( 5 m/s ... 60 m/s ) |
|
Wind direction
|
|
|
Measuring range
|
0 ... 360 °
|
|
Resolution
|
1 °
1 ° (standard) |
|
Accuracy
|
±2 ° WS > 1 m/s
|
|
Virtual temp.
|
|
|
Measuring range
|
-50 ... +70 °C
|
|
Resolution
|
0.1 K
|
|
Accuracy
|
±2 K
|
|
Data output digital
|
|
|
Interface
|
RS485 / RS422
|
|
Baudrate
|
1200 ... 921600 Baud
|
|
Data values
|
instant. values, average values, standard deviation
|
|
Output range
|
1 per 10 msec up to
1 per 10 sec |
|
Status signals
|
heating, distance error, Temperature of meas section
|
|
Protocol
|
ASCII / MODBUS RTU
|
|
Data output analog
|
|
|
Wind speed
|
0 ... 20 mA
4 ... 20 mA 0 ... 10 V 2 ... 10 V |
|
Stromausgang
|
max. 300 Ω
|
|
Wind direction
|
0 ... 20 mA
4 ... 20 mA 0 ... 10 V 2 ... 10 V |
|
Voltage output
|
min. 3000 Ω
|
|
Resolution
|
16 bit
|
|
Data input analog (alternative)
|
|
|
Chanels
|
3
|
|
Resolution
|
16 bit
|
|
Operating voltage
|
|
|
Electronic
|
8 ... 60V DC or
12 ... 42 V AC / 1.2 W |
|
Heating
|
24 V AC/DC, max. 250 W
|
|
Heating
|
|
|
Heated compontents
|
bottom plate, cover plate,
ultrasonic transducers |
|
General
|
|
|
Bus operation
|
up to 98 sensors
|
|
Electr. connection
|
8 pol. connector
|
|
Mounting
|
e.g. Mast tube Ø 50mm
|
|
Housing
|
AL, hard-snodized
|
|
Protection
|
IP 68
|
|
Dimension
|
Ø 200 mm x 144 mm
|
|
Weight
|
approx. 2 kg
|
- Ultrasonic Bedienungsanleitung
- Ultrasonic Kurzanleitung
- Ultrasonic Manual
- Ultrasonic Manual short
- Winddisplay Bedienungsanleitung
- Winddisplay Manual
- Classic Bedienungsanleitung
- Classic Manual
- Winddisplay Specification
- Winddisplay Spezifikation
- Classic Specification
- Ultrasonic Specification
- Classic Spezifikation
- Ultrasonic Spezifikation
- Thies Katalog Wind
- Thies Catalogue Wind
- Measuring unit
- 20m connection cable
- LED display unit